OTT MetSystems

System cabinets with integrated components for automatic weather stations

The rugged lockable control cabinet of the OTT MetSystems is designed for automatic meteorological stations. it is equipped with components for power supply as well as with the IP datalogger OTT netDL for saving and remotely transferring meteorological data. The datalogger is preconfigured for use with the precipitation gauge OTT Pluvio² and optionally also for Lufft-weather sensors. This simplifies the set up of sensors. The high quality of the properly installed components guarantees a long useful life.

  • Compact solution for automatic weather stations
  • Synoptic and climatological weather stations
  • Mains power
  • Cellular, Ethernet
Vyžádat nabídku nebo poradenství
  • Standardised configuration resulting in particularly attractive value for your money
  • Top-quality components, professionally installed and properly wired, threfore long useful life
  • Significantly less effort required for setting up a measuring station; with different preconfigured proven weather sensors depending on the system version
  • Remote data transfer via GSM/GPRS, 3G or LAN thanks to efficient modbus enabled IP-datalogger with integrated modem; supports all major transfer protocols
  • Standard interfaces provide flexibility – any SDI-12- or RS-485-sensor may be connected; additional analogue connections, depending on the system version
  • Rugged, lockable stainless steel system cabinet with built-in breather gland for ventilation and drainage - best possible protection for all components; water-proof cable glands for easy sensor connection
  • Convenient stainless steel mast mounting bracket for easy installation to masts of 1" ... 4", alternatively stainless steel wall bracket (both available as accessories).

 

 

The MetSystems are optimised for precipitation gauging stations as well as for stations measuring various meteorological parameters.

  • Synoptic weather stations
  • Climatological weather stations
  • Hydrological weather stations

They are recommended for use in automatic weather stations (AWS/AWOS), for weather services, for any meteorological application in hydrology and agriculture, for airports and motorways, for use in urban areas etc. 

Control cabinet
Dimensions (W x H x D) 380 mm x 500 mm x 210 mm
Housing stainless steel, lockable , with breather gland
Protection class IP66 (vertical installation)
Max. battery dimensions (W x H x D) Systems A/B:
190 mm x 175 mm x 130 mm
Systems C/D:
65 mm x 96 mm x 151 mm
Temperature range for control cabinet -25 °C ... +70 °C incl. components
Power supply
Power Control Unit for mains power operation OTT PCU12
Power supply 24 V/50 W
24 V/240 W (only for version C)
optional: 12 V/6.5 Ah rechargeable battery
Overvoltage protection for power supply SPD acc. to EN 61643-11: Typ 3
SPD acc. to IEC 61643-1/-11: Class III
OTT netDL 500/1000 IP datalogger built-in modem (GSM/GPRS or 3G) and flat antenna
Communication interfaces USB host and USB device,
RS-232 (full DB9),
Ethernet (netDL 1000)
Sensor interfaces SDI-12, RS-485 (SDI-12),
2 x status/pulse input,
2 x switching output,
4 x analogue, may be expanded
up to 8 (Systems C and D)
Download PDF